Senville 60K BTU Central Split System with 16 SEER2 Heat Pump Condenser and Evaporator A-Coil (SENDC-60CO)

SenvilleSKU: SENDC-60CO-16

Price:
Sale price$4,199.99 Regular price$5,459.99SAVE 23%
Backorder
Estimated restock: 2-4 Weeks
Free Curbside Delivery — carrier calls to schedule

Free Curbside Delivery

Included on every order
Ships free by freight carrier. Your order leaves the warehouse tracked, on a palletized freight truck.
The carrier calls ahead. You'll schedule a delivery window that works for you before the truck heads out.
Delivered to the curb. The item is placed at the end of your driveway. Moving it inside is your responsibility, so plan to have help on hand for heavy pieces.
Before you sign: inspect the packaging for damage. Signing the delivery receipt confirms it arrived in good condition.
In-Home Protection Plan
Home Outlet Direct + CPS

Add an Extended Protection Plan by CPS and Enjoy Peace of Mind!

Protection Plan Benefits:
  • Covers 100% parts and labor for product defects in materials and workmanship
  • Replacement of product if it cannot be repaired
  • No deductibles
  • Protection from dust, heat and internal humidity damage
  • Damage caused by power surges
  • In-home service
Full Coverage Details
No deductibles
International coverage
Easy claims process

Description

The Senville SENDC-60CO is a 5-ton, 60,000 BTU central split heat pump system for homes that already have a forced-air furnace. It pairs the SENDC-60HF-OG outdoor heat pump condenser with the SENDC-60CO-C indoor evaporator A-coil. The A-coil mounts on your existing furnace and uses the furnace blower to move conditioned air through your ductwork, so you can add central cooling and heat pump heating without replacing the furnace or adding an air handler.

The outdoor unit runs a variable-speed twin rotary compressor powered by Inverter Technology, keeps heating down to -22°F (-30°C), and is sized for larger spaces up to 2,000 square feet. As a matched pairing, the system is AHRI-rated at 16 SEER2, 10 EER2 and 8.3 HSPF2-4 on R454B refrigerant, and the condenser moves up to 2,649 CFM at a 64 dBA sound level. The multi-position A-coil installs horizontally or vertically, uses a durable aluminum coil, includes an R454B refrigerant sensor, and works with a WiFi-enabled wired controller or a compatible third-party 24V thermostat.

Features

  • 5-Ton Matched System - The SENDC-60HF-OG condenser and SENDC-60CO-C A-coil are a matched 60,000 BTU pairing designed for larger spaces and demanding cooling needs, cooling areas up to 2,000 square feet.
  • Variable-Speed Inverter Compressor - The outdoor unit's twin rotary compressor (ETPQ480D66UMU1) is a variable-speed design powered by Inverter Technology for efficient, consistent heating and cooling.
  • AHRI-Certified Ratings - Rated at 16 SEER2, 10 EER2, 8.3 HSPF2-4 and 2.8 COP as a matched condenser and coil pairing.
  • Heating Down to -22°F - Inverter heat pump technology keeps delivering heat in freezing weather, with operation down to -22°F (-30°C).
  • Multi-Position A-Coil - The SENDC-60CO-C A-coil installs horizontally or vertically on your existing furnace.
  • Durable Aluminum Coil - The A-coil is built with a durable aluminum coil and is designed for easy maintenance.
  • R454B Refrigerant with Sensor - The system runs on R454B refrigerant, and the A-coil includes an R454B refrigerant sensor.
  • Flexible Controls - Operates with a WiFi-enabled wired controller or a compatible third-party 24V thermostat.
  • 10-Year Compressor Warranty - Backed by a 10-year warranty on the compressor and a 5-year warranty on parts.

Please Note

  • Professional installation is required. This system is recommended for installation by a licensed HVAC professional only.
  • Package includes the SENDC-60HF-OG outdoor heat pump condenser and the SENDC-60CO-C indoor evaporator A-coil. An existing furnace with a working blower is required and is not included; no air handler is included or needed, because the A-coil relies on the furnace blower to move air.
  • Line Set Length option: choose a 16 Ft., 25 Ft. or 50 Ft. installation kit (line set) to match the distance between the outdoor unit and the coil, or select No Line Set if you are sourcing your own line set.
  • Electrical: the outdoor unit requires a 208/230V, 1Ph, 60Hz circuit (187-253 voltage range) with 40A minimum circuit ampacity (MCA) and 40A maximum overcurrent protection (MOP). The coil controls run on 24V, 1Ph, 60Hz.
  • Controls: the system is compatible with a WiFi-enabled wired controller or a third-party 24V thermostat. Confirm your controller or thermostat selection with your installer.
  • Efficiency ratings (16 SEER2, 10 EER2, 8.3 HSPF2-4) are AHRI-certified for this specific condenser and coil pairing. Have your installer confirm that your existing furnace blower provides suitable airflow for a 5-ton coil.
GENERAL INFORMATION
Model Number
SENDC-60CO
Outdoor Unit Model
SENDC-60HF-OG
Coil Model Number
SENDC-60CO-C
Style
Central Air Conditioner with Heat Pump
Compressor Type
Twin Rotary (ETPQ480D66UMU1)
Certifications
AHRI
DIMENSIONS & WEIGHT
Outdoor Dimensions (W×D×H)
37-1/2 × 16-3/8 × 52-1/2 in
Outdoor Package Dimensions (W×D×H)
43-1/8 × 19-1/2 × 58-1/4 in
Outdoor Net/Gross Weight
242 / 275 lbs
EVAPORATOR COIL
Coil Installation Position
Multi-position installation (horizontal or vertical)
Coil Material
Aluminum
Refrigerant Sensor
R454B refrigerant sensor
Indoor Dimensions (W×D×H)
21-5/8 × 21-1/2 × 27-3/4 in
Indoor Package Dimensions (W×D×H)
31-1/8 × 25 × 25-5/8 in
Indoor Net/Gross Weight
97 / 115 lbs
CAPACITY & PERFORMANCE
Capacity
60,000 BTU
SEER2
16.0
EER2
10.0
HSPF2-4
8.3
COP
2.8
Cooling Capacity (BTU)
54000
Cooling Range (BTU)
11400~56300
Cooling Input Range (W)
1540~6430
Cooling Current Range (A)
7.2~28.4
Heating Capacity (BTU)
56000
Heating Range (BTU)
8100~64500
Heating Input Range (W)
725~5970
Heating Current Range (A)
4~30.6
Minimum Outdoor Heating Temperature
-22°F / -30°C
Outdoor Airflow (Max)
2,649 CFM
Moisture Removal (L/H)
5.87
NOISE LEVELS
Outdoor Sound Level
64 dBA
ELECTRICAL REQUIREMENTS
Outdoor Power Supply
208/230V, 1Ph, 60Hz
Voltage Range
187-253
Outdoor MCA
40A
Outdoor MOP
40A
Max. Fuse (A)
40
Indoor Power Supply
24V, 1Ph, 60Hz
REFRIGERANT & PIPING
Refrigerant
R454B
Refrigerant Type / Charge oz
R454B / 183.42
CONTROLS & CONNECTIVITY
Thermostat Type
Wall Remote Thermostat
Control Options
WiFi-enabled wired controller or third-party 24V thermostats
WARRANTY
Warranty
10 Years Compressor / 5 Years Parts
Shipping
  • Free Shipping on all orders.
  • Large Appliances: Ship via Curbside Delivery — the carrier delivers to your property but not inside your home.
  • Small Items: Ship via standard ground delivery (FedEx or similar), such as small appliances, range hoods, sinks, faucets, and accessories.
Full shipping policy
Returns
  • 30-Day Return Policy: Return requests must be submitted within 30 days of your delivery date. We cannot process returns after this period.
  • Return Requirements: Products must be unused, uninstalled, and in their original packaging (including box and pallet) to qualify.
  • Restocking Fee: A restocking fee may apply and varies by brand.
Full returns policy
Authorized Senville Dealer
Full manufacturer warranty on every Senville product we sell.

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Central Split System FAQs

What is a central HVAC system?
A central HVAC system uses a network of ducts to heat and cool your entire home from a single unit. It typically consists of an outdoor condenser (or heat pump) and an indoor air handler connected by refrigerant lines, distributing conditioned air through vents in every room.
What's the difference between a heat pump system and a traditional A/C system?
A heat pump can both heat and cool your home by reversing its refrigerant cycle, making it a year-round solution without a separate furnace. A traditional central A/C system only cools — you'd pair it with a gas furnace or electric air handler for heating. Heat pumps are generally more energy-efficient in moderate climates.
What size central HVAC system do I need?
Sizing depends on your home's square footage, insulation, climate zone, and ceiling height. As a general rule: 1 ton of cooling covers roughly 400–600 sq ft. A 2,000 sq ft home typically needs a 3–4 ton system. Use our live chat to speak with an HVAC specialist who can help you size correctly.
Can I buy a central HVAC system online and install it myself?
You can purchase central HVAC equipment online and save significantly versus buying through a local contractor. However, installation must be performed by a licensed HVAC technician in most states — the refrigerant handling and electrical work require certification. We recommend buying the equipment here and hiring a local installer separately.
What SEER2 rating should I look for?
SEER2 (Seasonal Energy Efficiency Ratio 2) measures cooling efficiency — higher numbers mean lower energy costs. Federal minimums are 14–15 SEER2 depending on your region. For the best long-term savings, look for systems rated 16 SEER2 or higher. Many of our MRCOOL and Senville systems reach 17–18 SEER2.
Does Home Outlet Direct offer financing for central HVAC purchases?
Yes. Financing is available on qualifying orders, making it easier to invest in a high-efficiency central HVAC system without paying everything upfront. See our financing page for details on terms and eligibility.
Do central HVAC systems from Home Outlet Direct come with a warranty?
All systems come with the manufacturer's warranty. We also offer extended warranty and protection plans for added peace of mind. Brands like MRCOOL and Goodman are backed by industry-leading coverage.