Goodman 2 Ton 13.4 SEER2 Central Air Conditioner Condenser with Ceiling Mounted Air Handler & 6kW Heat Kit

Goodman 2 Ton 13.4 SEER2 Central Air Conditioner Condenser with Ceiling Mounted Air Handler & 6kW Heat Kit

SKU: GLXS3BN2410ACST24LU1306

Sale price$2,827.00 Regular price$3,678.00



In Stock Estimated delivery: Jul 29th-12th
  • Secure Payment
    Amazon American Express Apple Pay Diners Club Discover Google Pay Mastercard PayPal Shop Pay Venmo Visa
    Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
  • Free Shipping*
  • 30-Day Return Policy⁺

Package Overview

Goodman 2 Ton 13.4 SEER2 Central Air Conditioning System | Air Handler | R-32 Refrigerant | Covers 1,000-1,300 Sq. Ft.

Features:

  • Condenser Cooling Capacity: 24K BTU (2 Ton)
  • Energy Efficiency: 13.4 SEER2
  • Recommended Coverage Area: 1,000-1,300 Sq. Ft.
  • Installation Type: Split System with Air Handler
  • Refrigerant: R-32
  • Voltage: 208/230 V / 1 Ph / 60 Hz
  • Compressor: Single Stage
  • Air Handler: Multi-Speed ECM Motor
  • AHRI Certified & ETL Listed

Package Includes:

Description
Product Specs
Manuals & Guides

The Goodman GLXS3B Split System Air Conditioner delivers 13.4 SEER2 efficiency with R-32 refrigerant at 2 Ton capacity. Features single-stage cooling and durable powder-painted cabinet with easy service access. Optimized for next-generation R-32 refrigerant with lower GWP. AHRI Certified and ETL Listed.

Features
  • Energy-Efficienct Compressor
  • Fully charged for 15' of tubing length
  • Copper tube/ enhanced aluminum fin coil-5mm diameter
  • Factory-installed filter drier
  • Sweat connection service valves with easy access to gauge ports
  • Enclosed contactor with lug connection
  • High-pressure switch
  • Capacitors with extended life
  • AHRI Certified
  • ETL Listed
Cabinet Features
  • Removable grille-style top design compliant with UL 60335-2-40
  • Venturi for increased velocity of airflow
  • Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
  • Wire fan discharge grille
  • Steel louver coil guard
  • Top and side maintenance access
  • Single-panel access to controls with space provided for field-installed accessories
  • When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
DIMENSIONS & WEIGHT
Height 27.5 in
Width 26 in
Depth 26 in
Weight 114 lb
GENERAL INFORMATION
Brand Goodman
Series GLXS3B
SKU GLXS3BN2410
Product Category Unitary
Unit Type Outdoor
Manufacturer Goodman
Product Features
  • Energy-Efficienct Compressor
  • Fully charged for 15' of tubing length
  • Copper tube/ enhanced aluminum fin coil-5mm diameter
  • Factory-installed filter drier
  • Sweat connection service valves with easy access to gauge ports
  • Enclosed contactor with lug connection
  • High-pressure switch
  • Capacitors with extended life
  • AHRI Certified
  • ETL Listed
CAPACITY & PERFORMANCE
Tonnage 2.0
Cooling BTU 23000 Btu/H
Cooling Operating Range 55 °F to 115 °F
SEER2 13.4
EER2 11.2
COMPRESSOR & MOTORS
Compressor Type Rotary
Compressor Stages Single Stage
NOISE LEVELS
Decibel Level (dBA) 74 dBA
ELECTRICAL REQUIREMENTS
Voltage/Phase/Hz 208/230 V / 1 Ph / 60 Hz
Max Breaker Size 15 A
Min. Breaker Size 10.94 A
REFRIGERANT & PIPING
Refrigerant R-32
Factory Refrigerant Charge 53 oz
Liquid Line 3/8 in
Suction Line 3/4 in
Max Line Set Length 150 ft
SAFETY
ENERGY STAR® Certified No
Proposition 65 Warning Yes
WARRANTY
Warranty ALL PARTS - 5 YEARS PARTS
Goodman ACST Air Handler 2 Ton (ACST24LU1306)
Goodman ACST Air Handler 2 Ton (ACST24LU1306)
In Stock Estimated delivery: Jul 29th-12th
Description
Product Specs
Manuals & Guides

The Goodman ACST Air Handler offers dependable 2 Ton capacity with a multi-speed ECM motor for efficient and quiet performance. Equipped with a factory-installed TXV, all-aluminum evaporator coil, and electric heat options from 5-10 kW, this versatile unit handles both heating and cooling needs. Features galvanized-steel construction with R-32 refrigerant compatibility and factory-installed leak detection sensor. AHRI Certified and ETL Listed.

Features

  • Factory installed TXV for heat pump and cooling-only applications
  • All-Aluminum tube/aluminum fin coil
  • Direct-drive, resilient-mount, multi-speed motor
  • Sequence-controlled and rust-resistant nickel chromium heating elements of 5, 6, 8 and 10 kW
  • High-efficiency evaporator coil
  • Quiet operation
  • AHRI Certified
  • Suitable for both front and bottom return
  • Factory installed casing
  • UL 2-40 cerified
  • 10. ETL Listed
  • 1Suitable for free-return installation (non-ducted return air)
  • 1Galvanized-steel construction
  • 1Factory-installed pull-type disconnect
  • 1Easy service access
  • 1Optimized for use with R-32 refrigerant with factory installed leak detection sensor for A2L mitigation.

Cabinet Features

  • Primary/secondary drain connection in a high-temperature plastic drain pan
  • Suitable for free-return installation (non-ducted return air)
  • Galvanized-steel construction
  • Factory-installed pull-type disconnect
  • Easy service access
  • Suitable for both front and bottom return
  • Factory installed casing
DIMENSIONS & WEIGHT
Height 11 in
Width 54-1/5 in
Depth 22.2 in
Weight 97 lb
GENERAL INFORMATION
Brand Goodman
Series ACST
SKU ACST24LU1306
Product Category Unitary
Unit Type Indoor
Manufacturer Goodman
Product Features 1. Factory installed TXV for heat pump and cooling-only applications;2. All-Aluminum tube/aluminum fin coil;3. Direct-drive, resilient-mount, multi-speed motor;3. Sequence-controlled and rust-resistant nickel chromium heating elements of 5, 6, 8 and 10 kW;4. High-efficiency evaporator coil;5. Quiet operation;6. AHRI Certified;7. Suitable for both front and bottom return;8. Factory installed casing;9. UL 2-40 cerified;10. ETL Listed;11. Suitable for free-return installation (non-ducted return air);12. Galvanized-steel construction;13. Factory-installed pull-type disconnect;14. Easy service access;15. Optimized for use with R-32 refrigerant with factory installed leak detection sensor for A2L mitigation.
CAPACITY & PERFORMANCE
Tonnage 2.0
ELECTRICAL REQUIREMENTS
Voltage/Phase/Hz 208/230 V / 1 Ph / 60 Hz
Max Breaker Size 30/35 A
Min. Breaker Size 29.6/33.8 A
REFRIGERANT & PIPING
Factory Refrigerant Charge 0 oz
Liquid Line 3/8 in
Suction Line 3/4 in
SAFETY
Proposition 65 Warning Yes
WARRANTY
Warranty ALL PARTS - 5 YEARS PARTS

Shipping & Returns