{"product_id":"senville-60k-btu-top-discharge-central-split-system-with-17-7-seer2-hyper-heat-pump-condenser-and-ducted-air-handler-sentc-60td","title":"Senville 60K BTU Top Discharge Central Split System with 17.7 SEER2 Hyper Heat Pump Condenser and Ducted Air Handler (SENTC-60TD)","description":"\u003cp\u003eThe Senville SENTC-60TD is a 5 ton (60,000 BTU) top discharge central heat pump system that pairs a Hyper Heat inverter condenser with a ducted indoor air handler. It is built for large homes and light commercial spaces, delivering 55,000 BTU\/h of rated cooling and 57,000 BTU\/h of rated heating at 17.70 SEER2, with heating operation down to -4°F outdoors.\u003c\/p\u003e\n\u003cp\u003eA twin-rotary DC inverter compressor modulates output between 14,000 and 55,000 BTU\/h in cooling and 13,400 to 55,000 BTU\/h in heating, so the system runs at the speed the space calls for instead of cycling on and off. The ducted air handler moves up to 1,740 CFM on high, the system runs on R-32 refrigerant, and every configuration ships with a line set kit in your choice of 16 Ft. or 50 Ft.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5 Ton Hyper Heat Capacity\u003c\/strong\u003e - Rated for 55,000 BTU\/h of cooling and 57,000 BTU\/h of heating, sized for large homes and light commercial applications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-Climate Heating\u003c\/strong\u003e - Heats at outdoor temperatures down to -4°F, delivering 40,000 BTU\/h at 5°F and 33,000 BTU\/h at -4°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwin-Rotary DC Inverter Compressor\u003c\/strong\u003e - Variable-speed GMCC compressor modulates between 14,000 and 55,000 BTU\/h in cooling to hold steady temperatures and cut energy use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e17.70 SEER2 Efficiency\u003c\/strong\u003e - Rated 17.70 SEER2, 8.60 EER2, 8.00 HSPF2 (Region 4) and 3.31 COP in heating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Discharge Condenser\u003c\/strong\u003e - Outdoor unit discharges air upward from a 29-9\/64\" x 29-9\/64\" footprint, moving up to 3,050 CFM at 60 dB(A).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucted Air Handler\u003c\/strong\u003e - Indoor unit delivers 1,740 CFM on high and 750 CFM on low at 52.5 \/ 44 dB(A), with a 164 lb cabinet measuring 24-31\/64\" x 21-1\/32\" x 52-63\/64\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Weather Cooling\u003c\/strong\u003e - Cooling operating range of 5°F to 131°F outdoors, with 41,000 BTU\/h still available at 109°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-32 Refrigerant\u003c\/strong\u003e - Factory charged with 3.4 kg (119.9 oz) of R-32 and rated for line runs up to 246 ft with a 98.4 ft maximum height difference, using flared connections and 3\/8 in \/ 3\/4 in lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOptional Electric Heat Kit\u003c\/strong\u003e - Available with a 5KW, 10KW, 15KW or 20KW auxiliary heater for supplemental heat on the coldest days.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified\u003c\/strong\u003e - Listed with AHRI, with an AHRI certificate and EnergyGuide label published for the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlease Note\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional installation by a licensed HVAC technician is required. This system uses R-32 refrigerant, and indoor, outdoor and service manuals are available from Senville.\u003c\/li\u003e\n\u003cli\u003eThe package includes the outdoor Hyper Heat pump condenser and the indoor ducted air handler. The Line Set Length option selects the included line set kit: 16 Ft. or 50 Ft.\u003c\/li\u003e\n\u003cli\u003eHeat Kit \"None\" means no auxiliary heater is included. Choosing 5K, 10K, 15K or 20K adds an electric auxiliary heater of that rating for supplemental or backup heat.\u003c\/li\u003e\n\u003cli\u003eRequires 208\/230V, 60 Hz, single-phase power. Outdoor unit MCA \/ MOP is 39 A \/ 40 A; indoor unit MCA \/ MOP is 7 A \/ 15 A. Electrical requirements with an auxiliary heater installed are given in the installation manual.\u003c\/li\u003e\n\u003cli\u003eMaximum pipe length is 246 ft with a 98.4 ft maximum height difference. Longer line runs may require additional refrigerant at 0.52 oz\/ft (48 g\/m) per the installation manual.\u003c\/li\u003e\n\u003cli\u003eDuctwork and installation materials beyond the selected line set kit are not included.\u003c\/li\u003e\n\u003cli\u003eSpecifications shown are for the SENTC-60TD system as published by Senville.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Senville","offers":[{"title":"16 Ft. \/ None","offer_id":67608396791982,"sku":"SENTC-60TD-16","price":4699.99,"currency_code":"USD","in_stock":true},{"title":"16 Ft. \/ 5K","offer_id":67608396824750,"sku":"SENTC-60TD-05K-16","price":4849.99,"currency_code":"USD","in_stock":true},{"title":"16 Ft. \/ 10K","offer_id":67608396857518,"sku":"SENTC-60TD-10K-16","price":4899.99,"currency_code":"USD","in_stock":true},{"title":"16 Ft. \/ 15K","offer_id":67608396890286,"sku":"SENTC-60TD-15K-16","price":4949.99,"currency_code":"USD","in_stock":true},{"title":"16 Ft. \/ 20K","offer_id":67608396923054,"sku":"SENTC-60TD-20K-16","price":4999.99,"currency_code":"USD","in_stock":true},{"title":"50 Ft. \/ None","offer_id":67608396955822,"sku":"SENTC-60TD-50","price":4849.99,"currency_code":"USD","in_stock":true},{"title":"50 Ft. \/ 5K","offer_id":67608396988590,"sku":"SENTC-60TD-05K-50","price":4999.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 10K","offer_id":67608397021358,"sku":"SENTC-60TD-10K-50","price":5049.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 15K","offer_id":67608397054126,"sku":"SENTC-60TD-15K-50","price":5099.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 20K","offer_id":67608397086894,"sku":"SENTC-60TD-20K-50","price":5149.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/senville-5-ton-central-ac-unit-heat-pump-top-discharge__15141.1778032182.jpg?v=1790875272","url":"https:\/\/homeoutletdirect.com\/products\/senville-60k-btu-top-discharge-central-split-system-with-17-7-seer2-hyper-heat-pump-condenser-and-ducted-air-handler-sentc-60td","provider":"Home Outlet Direct","version":"1.0","type":"link"}