{"product_id":"senville-36k-btu-top-discharge-central-split-system-with-18-6-seer2-hyper-heat-pump-condenser-and-air-handler-sentc-36td","title":"Senville 36K BTU Top Discharge Central Split System with 18.6 SEER2 Hyper Heat Pump Condenser and Air Handler (SENTC-36TD)","description":"\u003cp\u003eThe Senville SENTC-36TD is a 3 ton (36,000 BTU) central heat pump split system that pairs a top discharge outdoor condenser with a ducted indoor air handler. Rated at 18.6 SEER2 and 9.0 HSPF2 (Region 4), it heats and cools medium-sized homes through ductwork while helping reduce energy costs. The top discharge configuration suits tighter installations, and the Hyper Heat inverter design keeps heating in outdoor temperatures down to –4°F.\u003c\/p\u003e\n\u003cp\u003eThe system runs on 208\/230V single-phase power and uses R-32 refrigerant with flared connections. Choose a 16 Ft. or 50 Ft. line set and, if needed, an auxiliary electric heat kit (5K, 10K, 15K or 20K) to match the installation.\u003c\/p\u003e\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3 Ton Hyper Heat System\u003c\/strong\u003e - Rated for 34,000 BTU\/h of cooling and 36,000 BTU\/h of heating, with a heating capacity range of 11,000 – 39,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18.6 SEER2 Efficiency\u003c\/strong\u003e - 18.6 SEER2, 11.7 EER2 and 9.0 HSPF2 (Region 4) ratings help lower operating costs year-round.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-Climate Heating\u003c\/strong\u003e - Delivers 27,000 BTU\/h at 5°F and 25,000 BTU\/h at –4°F outdoor, with a heating operating range of –4°F to 75°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide Cooling Range\u003c\/strong\u003e - Cools in outdoor temperatures from 5°F to 131°F and holds 32,000 BTU\/h at 109°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwin-Rotary DC Inverter Compressor\u003c\/strong\u003e - The variable-speed GMCC compressor modulates cooling output between 13,000 and 38,000 BTU\/h for steady, even comfort.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTop Discharge Condenser\u003c\/strong\u003e - Vertical airflow fits tighter outdoor placements; the 29-9\/64\" × 29-9\/64\" × 25\" cabinet weighs 143 lbs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucted Air Handler\u003c\/strong\u003e - The indoor unit moves 1,110 \/ 520 CFM (high \/ low) at 50 \/ 38 dB(A) and measures 21-1\/32\" × 21-1\/32\" × 49-7\/32\".\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQuiet Outdoor Operation\u003c\/strong\u003e - Outdoor unit rated at 58 dB(A) with 2,800 CFM of maximum airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong Line Set Capability\u003c\/strong\u003e - Supports up to 246 ft (75 m) of piping and 98.4 ft (30 m) of height difference with 3\/8 in liquid and 3\/4 in gas lines.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI Certified\u003c\/strong\u003e - Listed in the AHRI directory with an EnergyGuide label.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlease Note\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProfessional installation by a licensed HVAC technician is required.\u003c\/li\u003e\n\u003cli\u003ePackage includes the outdoor heat pump condenser and the indoor ducted air handler.\u003c\/li\u003e\n\u003cli\u003eLine Set Length selects the installation kit length (16 Ft. or 50 Ft.) supplied with the system. Additional refrigerant may be needed on longer runs at 0.52 oz\/ft (48 g\/m).\u003c\/li\u003e\n\u003cli\u003eHeat Kit selects an optional auxiliary electric heater (5K, 10K, 15K or 20K) for the air handler to provide supplemental heat; choose None if not required. Electrical requirements for the air handler increase when a heat kit is installed, so have your installer size the circuit accordingly.\u003c\/li\u003e\n\u003cli\u003eRequires a 208\/230V, 60 Hz, single-phase power supply. Outdoor unit MCA \/ MOP is 24 A \/ 30 A; indoor unit MCA \/ MOP is 5 A \/ 15 A.\u003c\/li\u003e\n\u003cli\u003eFactory charged with 2.9 kg (102.3 oz) of R-32 refrigerant.\u003c\/li\u003e\n\u003cli\u003eIndoor and outdoor installation manuals and a service manual are available from the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Senville","offers":[{"title":"16 Ft. \/ None","offer_id":67608395841710,"sku":"SENTC-36TD-16","price":3499.99,"currency_code":"USD","in_stock":true},{"title":"16 Ft. \/ 5K","offer_id":67608395874478,"sku":"SENTC-36TD-05K-16","price":3649.99,"currency_code":"USD","in_stock":false},{"title":"16 Ft. \/ 10K","offer_id":67608395907246,"sku":"SENTC-36TD-10K-16","price":3699.99,"currency_code":"USD","in_stock":false},{"title":"16 Ft. \/ 15K","offer_id":67608395940014,"sku":"SENTC-36TD-15K-16","price":3749.99,"currency_code":"USD","in_stock":false},{"title":"16 Ft. \/ 20K","offer_id":67608395972782,"sku":"SENTC-36TD-20K-16","price":3799.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ None","offer_id":67608396005550,"sku":"SENTC-36TD-50","price":3649.99,"currency_code":"USD","in_stock":true},{"title":"50 Ft. \/ 5K","offer_id":67608396038318,"sku":"SENTC-36TD-05K-50","price":3799.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 10K","offer_id":67608396071086,"sku":"SENTC-36TD-10K-50","price":3849.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 15K","offer_id":67608396103854,"sku":"SENTC-36TD-15K-50","price":3899.99,"currency_code":"USD","in_stock":false},{"title":"50 Ft. \/ 20K","offer_id":67608396136622,"sku":"SENTC-36TD-20K-50","price":3949.99,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0099\/2251\/0926\/files\/senville-3-ton-central-ac-unit-heat-pump-top-discharge__25855.1778032148.jpg?v=1790875262","url":"https:\/\/homeoutletdirect.com\/products\/senville-36k-btu-top-discharge-central-split-system-with-18-6-seer2-hyper-heat-pump-condenser-and-air-handler-sentc-36td","provider":"Home Outlet Direct","version":"1.0","type":"link"}